description: Driver for Winline ACDC power supply. Supports multiple Winline modules using CAN protocol either in fixed address mode or group discovery mode.
|
|
config:
|
|
can_device:
|
|
description: CAN interface name
|
|
type: string
|
|
default: can0
|
|
module_addresses:
|
|
description: >-
|
|
Module Addresses to use.
|
|
If you have multiple PSUs, use individual addresses and list them comma separated, e.g. "1,2".
|
|
type: string
|
|
default: ""
|
|
group_address:
|
|
description: >-
|
|
Group address. Use this if your PSUs are using automatic allocation of the addresses.
|
|
If you have multiple PSUs, set this number in accordance with the group dial
|
|
setting of the PSUs you want to use.
|
|
Can't use module addresses and group addresses at the same time, if both are set, the module addresses will be used.
|
|
type: integer
|
|
default: 0
|
|
device_connection_timeout_s:
|
|
description: >-
|
|
Timeout in seconds to wait for a module to respond before considering it offline.
|
|
CRITICAL SAFETY: Must be greater than module internal timeout to prevent overcurrent risk.
|
|
Recommended: 15s.
|
|
type: integer
|
|
default: 15
|
|
conversion_efficiency_export:
|
|
description: Conversion efficiency of the export mode.
|
|
type: number
|
|
default: 0.95
|
|
controller_address:
|
|
description: Controller address defaults to 0xF0.
|
|
type: integer
|
|
default: 240
|
|
min_export_voltage_V:
|
|
description: Minimum export voltage limit (V)
|
|
type: number
|
|
default: 50.0
|
|
max_export_voltage_V:
|
|
description: Maximum export voltage limit (V)
|
|
type: number
|
|
default: 1000.0
|
|
min_export_current_A:
|
|
description: Minimum export current limit (A)
|
|
type: number
|
|
default: 0.0
|
|
max_export_current_A:
|
|
description: Maximum export current limit (A) - will be updated by device rated values
|
|
type: number
|
|
default: 133.3
|
|
power_state_grace_period_ms:
|
|
description: Grace period in milliseconds to wait before verifying power state changes
|
|
type: integer
|
|
default: 2000
|
|
current_regulation_tolerance_A:
|
|
description: Current regulation tolerance (A)
|
|
type: number
|
|
default: 0.5
|
|
peak_current_ripple_A:
|
|
description: Peak current ripple (A)
|
|
type: number
|
|
default: 2
|
|
altitude_setting_m:
|
|
description: >-
|
|
Working altitude setting in meters. This affects the power derating of the modules
|
|
at high altitudes. Valid range: 1000-5000m. Default: 1000m (sea level).
|
|
type: integer
|
|
default: 1000
|
|
input_mode:
|
|
description: >-
|
|
Input mode for the power supply modules. AC mode for AC input, DC mode for DC input.
|
|
This setting affects the internal configuration of the modules.
|
|
type: string
|
|
default: "AC"
|
|
enum:
|
|
- "AC"
|
|
- "DC"
|
|
module_current_limit_point:
|
|
description: Percentage of the rated current that the module will use as the current limit point (0.0-3.3325)
|
|
type: number
|
|
default: 3.3325
|
|
provides:
|
|
main:
|
|
description: Main interface
|
|
interface: power_supply_DC
|
|
config: {}
|
|
metadata:
|
|
license: https://opensource.org/licenses/Apache-2.0
|
|
authors:
|
|
- Florin Mihut
|