GeoServer workspace Digitribe + InfluxDB support + data flow diagrams

This commit is contained in:
Eric FELIXINE
2026-05-04 18:13:48 -04:00
parent fb5b98043c
commit 42d1223b14
2 changed files with 130 additions and 1 deletions

View File

@@ -0,0 +1,68 @@
# Configuration GeoServer - Smart City Digital Twin
## État au 04 Mai 2026 (22h15)
### ✅ Réalisé
1. **Workspace créé** : `Digitribe` (via REST API)
- URL: https://geoserver.digitribe.fr/geoserver/web/?workspace=Digitribe
2. **Tentatives d'entrepôts** :
- `brokers_postgis` (docker-postgis-1) - créé mais connexion instable
- `digital_twin_postgis` (digital-twin-postgis) - base "digitribe" inexistante
- `digitribe_brokers` (docker-postgis-1, base "geoserver") - erreur "Unable to encrypt connection parameters"
- `brokers_shapefile` (Shapefile) - créé mais vide (pas de fichiers .shp)
### ❌ Problèmes rencontrés
- **Erreur** : "Failed to find the datastore factory" / "Unable to encrypt connection parameters"
- **Cause probable** : Paramètres de connexion PostGIS mal formatés ou problème de chiffrement GeoServer
- **Identifiants testés** :
- docker-postgis-1 : user=`geoserver`, password=`geoserver`, db=`geoserver`
- digital-twin-postgis : user=`gis_user`, password=`gis_pass` (probable)
- frost_http-database-1 : user=`sensorthings`, password=`Digitribe972` (probable)
### 📋 Configuration pour MapStore
Une fois l'entrepôt fonctionnel, voici comment l'utiliser dans MapStore :
```javascript
// Exemple de configuration MapStore (WMS)
{
"type": "wms",
"url": "https://geoserver.digitribe.fr/geoserver/wms",
"name": "Digitribe:broker_sensors",
"format": "image/png",
"workspace": "Digitribe"
}
```
### 🔄 Prochaines étapes (pour reprise)
1. **Corriger l'entrepôt PostGIS** :
- Vérifier que le container GeoServer peut joindre le container PostGIS
- Tester la connexion via `psql` depuis le container GeoServer
- Utiliser le format XML correct pour les paramètres chiffrés
2. **Ajouter des données spatiales** :
- Importer les données des capteurs (depuis InfluxDB ou FROST)
- Créer des vues géographiques dans PostGIS
3. **Publier les couches** :
- `broker_sensors` (positions des capteurs MQTT)
- `sensor_data` (données temps réel)
4. **Configurer MapStore** :
- Ajouter GeoServer comme source WMS/WFS
- Créer une carte avec les couches du workspace Digitribe
### 🔧 Commandes de diagnostic
```bash
# Tester la connexion depuis GeoServer
docker exec geoserver_stack-geoserver-1 psql -h digital-twin-postgis -U gis_user -d digitribe -c "\dt"
# Vérifier les logs GeoServer
docker logs geoserver_stack-geoserver-1 --tail 50 | grep -i "error\|datastore"
# Recréer l'entrepôt avec le bon format
curl -X PUT "https://geoserver.digitribe.fr/geoserver/rest/workspaces/Digitribe/datastores/digitribe_brokers" \
-u "admin:Digitribe972" \
-H "Content-Type: application/xml" \
-d '...' # (XML avec paramètres corrects)
```
---
**Fichiers** : `geoserver_config_status.md` (ce fichier)
**Statut** : Workspace ✅ | Entrepôts ⚠️ (à debugguer) | Prêt pour MapStore ❌

View File

@@ -29,6 +29,10 @@ import urllib.request, urllib.error
from datetime import datetime, timezone
from typing import Any
# InfluxDB support
import influxdb_client
from influxdb_client.client.write_api import SYNCHRONOUS
# =============================================================================
# Configuration
# =============================================================================
@@ -45,6 +49,24 @@ OR_REALM = os.environ.get("OR_REALM", "smartcity")
OR_TOKEN_REALM = os.environ.get("OR_TOKEN_REALM", "master") # Realm pour obtention token
FROST_URL = os.environ.get("FROST_URL", "http://frost_http-web-1:8080/FROST-Server/v1.1")
# InfluxDB config
ENABLE_INFLUX = os.environ.get("ENABLE_INFLUX", "1") == "1"
INFLUX_URL = os.environ.get("INFLUX_URL", "http://digital-twin-influxdb:8086")
INFLUX_ORG = os.environ.get("INFLUX_ORG", "digitribe")
INFLUX_BUCKET = os.environ.get("INFLUX_BUCKET", "iot_data")
INFLUX_TOKEN = os.environ.get("INFLUX_TOKEN", "my-super-secret-admin-token")
# Initialize InfluxDB client
_influx_client = None
_influx_write_api = None
if ENABLE_INFLUX:
try:
_influx_client = influxdb_client.InfluxDBClient(url=INFLUX_URL, token=INFLUX_TOKEN, org=INFLUX_ORG)
_influx_write_api = _influx_client.write_api(write_options=SYNCHRONOUS)
print(f"[INFLUX] ✅ Connected to {INFLUX_URL}")
except Exception as e:
print(f"[INFLUX] ❌ Connection failed: {e}")
SENSOR_COUNTS = {
"traffic": int(os.environ.get("SENSOR_COUNT_traffic", "3")),
"airquality": int(os.environ.get("SENSOR_COUNT_airquality", "2")),
@@ -724,7 +746,35 @@ def publish_openremote(sid: str, sensor: dict, values: dict) -> bool:
"attributes": attrs,
}
return _or_put(asset_id, payload)
# =============================================================================
def publish_influx(sid: str, sensor: dict, values: dict) -> bool:
"""Write sensor data to InfluxDB."""
if not _influx_write_api:
return False
try:
stype = sensor["type"]
lat = sensor.get("lat", BASE_LAT)
lon = sensor.get("lon", BASE_LON)
points = []
for field, value in values.items():
if isinstance(value, (int, float)):
p = influxdb_client.Point(stype)\
.tag("sensor_id", sid)\
.tag("location", sensor.get("name", sid))\
.field(field, float(value))\
.field("lat", float(lat))\
.field("lon", float(lon))
points.append(p)
if points:
_influx_write_api.write(bucket=INFLUX_BUCKET, record=points)
print(f" 📈 InfluxDB: {len(points)} points written")
return True
except Exception as e:
print(f" ⚠️ InfluxDB → {e}")
return False
def main():
print("╔══════════════════════════════════════════════════╗")
print("║ Smart City Simulator — Martinique ║")
@@ -813,6 +863,17 @@ def main():
ok_fr = publish_frost(sid, sensor, field, val)
print(f" 📊 FROST: {'' if ok_fr else ''}")
# --- InfluxDB ---
if ENABLE_INFLUX:
influx_vals = {}
for field, val_range in ranges.items():
if isinstance(val_range, tuple) and len(val_range) == 2:
lo, hi = val_range
if isinstance(lo, (int, float)):
influx_vals[field] = round(random.uniform(lo, hi), 1)
ok_influx = publish_influx(sid, sensor, influx_vals)
print(f" 📈 InfluxDB: {'' if ok_influx else ''}")
# --- BunkerM HTTP ---
if os.getenv("BUNKERM_HTTP", "0") == "1":
ok_bunkerm = publish_bunkerm(sid, sensor, payload_mqtt)