description: Module implementing the LEM DCBM 400/600 power meter driver adapter via HTTP.
|
|
config:
|
|
ip_address:
|
|
description: IP Address of the power meter API.
|
|
type: string
|
|
port:
|
|
description: Port of the power meter API.
|
|
type: integer
|
|
default: 80
|
|
interface:
|
|
description: Bind to a specific network interface. If left empty, the module will bind to all interfaces.
|
|
type: string
|
|
default: ""
|
|
meter_tls_certificate:
|
|
description: The DCBM's HTTPS certificate, in PEM format. If provided, HTTPS will be used. If left empty, regular HTTP will be used. Note that this does not affect the default port - specify a port explicitly if you wish to use a port other than 80.
|
|
type: string
|
|
default: ""
|
|
ntp_server_1_ip_addr:
|
|
description: The IPv4 address (in 4-octet form W.X.Y.Z) of the first NTP server to use for time sync. If this is left empty, NTP will not be configured on the DCBM - its time will be synced with EVerest's system time instead.
|
|
type: string
|
|
default: ""
|
|
ntp_server_1_port:
|
|
description: The port (1-65535) of the first NTP server.
|
|
type: integer
|
|
default: 123
|
|
ntp_server_2_ip_addr:
|
|
description: The IPv4 address (in 4-octet form W.X.Y.Z) of the second NTP server to use for time sync. This is ignored if ntp_server_1_ip_addr is empty.
|
|
type: string
|
|
default: ""
|
|
ntp_server_2_port:
|
|
description: The port (1-65535) fof the second NTP server.
|
|
type: integer
|
|
default: 123
|
|
meter_timezone:
|
|
description: The timezone offset (ignored if NTP servers are set) - it can go from -11 to +14 for hours and 00, 15, 30, 45 for minutes
|
|
type: string
|
|
default: "+00:00"
|
|
meter_dst:
|
|
description: The Daylight Saving Time (DST) settings (ignored if NTP is set)
|
|
type: string
|
|
default: '{"activated": false, "offset": 60, "start": {"order": "last", "day": "sunday", "month": "march", "hour": "T01:00Z"}, "end": {"order": "last", "day": "sunday", "month": "october", "hour": "T01:00Z" }}'
|
|
resilience_initial_connection_retries:
|
|
description: For the controller resilience, the number of retries to connect to the powermeter at module initialization.
|
|
type: integer
|
|
default: 25
|
|
resilience_initial_connection_retry_delay:
|
|
description: For the controller resilience, the delay in milliseconds before a retry attempt at module initialization..
|
|
type: integer
|
|
default: 10000
|
|
resilience_transaction_request_retries:
|
|
description: For the controller resilience, the number of retries to connect to the powermeter at a transaction start or stop request.
|
|
type: integer
|
|
default: 3
|
|
resilience_transaction_request_retry_delay:
|
|
description: For the controller resilience, the delay in milliseconds before a retry attempt at a transaction start or stop request.
|
|
type: integer
|
|
default: 250
|
|
cable_id:
|
|
description: The cable loss compensation level to use. This allows compensating the measurements of the DCBM with a resistance.
|
|
type: integer
|
|
default: 0
|
|
tariff_id:
|
|
description: Used for a unique transaction tariff designation
|
|
type: integer
|
|
default: 0
|
|
IT:
|
|
description: >-
|
|
OCMF Identification Type (set on device at startup via /settings/ocmfId/IT).
|
|
Values per LEM DCBM Communication Protocol 4.2.10.3:
|
|
0=NONE, 1=DENIED, 2=UNDEFINED, 3=ISO14443, 4=ISO15693,
|
|
5=EMAID, 6=EVCCID, 7=EVCOID, 8=ISO7812, 9=CARD_TXN_NR,
|
|
10=CENTRAL, 11=CENTRAL_1, 12=CENTRAL_2, 13=LOCAL, 14=LOCAL_1,
|
|
15=LOCAL_2, 16=PHONE_NUMBER, 17=KEY_CODE.
|
|
A value of -1 means the field is not set on the device.
|
|
By setting this value you can control the content of the ID field of OCMF record.
|
|
If this value is not set, ID is set to the transaction id.
|
|
Please check the device documentation for more details.
|
|
|
|
WARNING: The device documentation states: "For correct usage the IT fields shall
|
|
be set once to the corresponding protocol used (or kept to NONE as per default value),
|
|
and not be changed during the lifetime of the DCBM due to current software limitation."
|
|
type: integer
|
|
minimum: -1
|
|
maximum: 17
|
|
default: -1
|
|
SC:
|
|
description: SC (OCMF/transaction fields)
|
|
type: integer
|
|
default: 0
|
|
UV:
|
|
description: User SW Version (OCMF/transaction fields)
|
|
type: string
|
|
default: ""
|
|
UD:
|
|
description: UD (OCMF/transaction fields)
|
|
type: string
|
|
default: ""
|
|
temperature_warning_level_C:
|
|
description: >-
|
|
Temperature warning threshold in degrees Celsius. If the maximum of temperatureH
|
|
and temperatureL exceeds this value for at least temperature_min_time_as_valid_ms,
|
|
a VendorWarning is raised. Charging continues. Default of 5000 effectively disables this.
|
|
type: number
|
|
default: 5000
|
|
temperature_error_level_C:
|
|
description: >-
|
|
Temperature error threshold in degrees Celsius. If the maximum of temperatureH
|
|
and temperatureL exceeds this value for at least temperature_min_time_as_valid_ms,
|
|
a VendorError is raised. Charging is stopped. Default of 5000 effectively disables this.
|
|
type: number
|
|
default: 5000
|
|
temperature_hysteresis_K:
|
|
description: >-
|
|
Hysteresis in Kelvin for clearing temperature warnings and errors.
|
|
A warning is cleared when max temperature drops below warning_level - hysteresis.
|
|
An error is cleared when max temperature drops below error_level - hysteresis.
|
|
type: number
|
|
default: 3
|
|
minimum: 0
|
|
temperature_min_time_as_valid_ms:
|
|
description: >-
|
|
Minimum time in milliseconds that the temperature must continuously exceed
|
|
the warning or error level before the corresponding event is raised.
|
|
type: integer
|
|
default: 5000
|
|
minimum: 0
|
|
command_timeout_ms:
|
|
description: The timeout in milliseconds for a HTTP command to the LEM power meter.
|
|
type: integer
|
|
default: 5000
|
|
maximum: 20000
|
|
minimum: 1000
|
|
|
|
provides:
|
|
main:
|
|
description: This is the main unit of the module
|
|
interface: powermeter
|
|
metadata:
|
|
license: https://opensource.org/licenses/Apache-2.0
|
|
authors:
|
|
- Valentin Dimov, valentin.dimov@pionix.de
|
|
- Fabian Klemm, fabian.klemm@pionix.de
|