description: >-
Errors for EvseManager
All error codes that begin with MREC need to be implemented to fulfill the Minimum Required Error Codes defined by the ChargeX consortium:
https://inl.gov/content/uploads/2023/07/ChargeX_MREC_Rev5_09.12.23.pdf
errors:
- name: Internal
description: Internal error of the state machine
- name: MREC4OverCurrentFailure
description: Over current event
- name: MREC5OverVoltage
description: Over voltage event
- name: MREC9AuthorizationTimeout
description: No authorization was provided within timeout after plugin
- name: PowermeterTransactionStartFailed
description: Transaction could not be started at the powermeter
- name: Inoperative
description: Charging is not possible. Usually caused by another error from one of the requirements.
- name: MREC22ResistanceFault
description: An Isolation Monitoring Device tripped due to low resistance to the chassis during active charging.
- name: MREC11CableCheckFault
description: Cable check failed. Isolation monitor self test failed before charging.
- name: VoltagePlausibilityFault