// SPDX-License-Identifier: Apache-2.0
|
|
// Copyright Pionix GmbH and Contributors to EVerest
|
|
#ifndef MAIN_POWERMETER_IMPL_HPP
|
|
#define MAIN_POWERMETER_IMPL_HPP
|
|
|
|
//
|
|
// AUTO GENERATED - MARKED REGIONS WILL BE KEPT
|
|
// template version 3
|
|
//
|
|
|
|
#include <generated/interfaces/powermeter/Implementation.hpp>
|
|
|
|
#include "../GenericPowermeter.hpp"
|
|
|
|
// ev@75ac1216-19eb-4182-a85c-820f1fc2c091:v1
|
|
// insert your custom include headers here
|
|
#include <optional>
|
|
#include <string>
|
|
// ev@75ac1216-19eb-4182-a85c-820f1fc2c091:v1
|
|
|
|
namespace module {
|
|
namespace main {
|
|
|
|
struct Conf {
|
|
std::string model;
|
|
int powermeter_device_id;
|
|
int modbus_base_address;
|
|
};
|
|
|
|
class powermeterImpl : public powermeterImplBase {
|
|
public:
|
|
powermeterImpl() = delete;
|
|
powermeterImpl(Everest::ModuleAdapter* ev, const Everest::PtrContainer<GenericPowermeter>& mod, Conf& config) :
|
|
powermeterImplBase(ev, "main"), mod(mod), config(config){};
|
|
|
|
// ev@8ea32d28-373f-4c90-ae5e-b4fcc74e2a61:v1
|
|
// insert your public definitions here
|
|
// ev@8ea32d28-373f-4c90-ae5e-b4fcc74e2a61:v1
|
|
|
|
protected:
|
|
// command handler functions (virtual)
|
|
virtual types::powermeter::TransactionStartResponse
|
|
handle_start_transaction(types::powermeter::TransactionReq& value) override;
|
|
virtual types::powermeter::TransactionStopResponse handle_stop_transaction(std::string& transaction_id) override;
|
|
|
|
// ev@d2d1847a-7b88-41dd-ad07-92785f06f5c4:v1
|
|
// insert your protected definitions here
|
|
// ev@d2d1847a-7b88-41dd-ad07-92785f06f5c4:v1
|
|
|
|
private:
|
|
const Everest::PtrContainer<GenericPowermeter>& mod;
|
|
const Conf& config;
|
|
|
|
virtual void init() override;
|
|
virtual void ready() override;
|
|
|
|
// ev@3370e4dd-95f4-47a9-aaec-ea76f34a66c9:v1
|
|
enum PowermeterRegisters {
|
|
// do not change order or index of these elements!
|
|
ENERGY_WH_IMPORT_TOTAL,
|
|
ENERGY_WH_IMPORT_L1,
|
|
ENERGY_WH_IMPORT_L2,
|
|
ENERGY_WH_IMPORT_L3,
|
|
ENERGY_WH_EXPORT_TOTAL,
|
|
ENERGY_WH_EXPORT_L1,
|
|
ENERGY_WH_EXPORT_L2,
|
|
ENERGY_WH_EXPORT_L3,
|
|
POWER_W_TOTAL,
|
|
POWER_W_L1,
|
|
POWER_W_L2,
|
|
POWER_W_L3,
|
|
VOLTAGE_V_DC,
|
|
VOLTAGE_V_L1,
|
|
VOLTAGE_V_L2,
|
|
VOLTAGE_V_L3,
|
|
REACTIVE_POWER_VAR_TOTAL,
|
|
REACTIVE_POWER_VAR_L1,
|
|
REACTIVE_POWER_VAR_L2,
|
|
REACTIVE_POWER_VAR_L3,
|
|
CURRENT_A_DC,
|
|
CURRENT_A_L1,
|
|
CURRENT_A_L2,
|
|
CURRENT_A_L3,
|
|
FREQUENCY_HZ_L1,
|
|
FREQUENCY_HZ_L2,
|
|
FREQUENCY_HZ_L3,
|
|
NUM_PM_REGISTERS
|
|
};
|
|
|
|
enum ModbusFunctionType {
|
|
READ_HOLDING_REGISTER,
|
|
READ_INPUT_REGISTER,
|
|
REGISTER_TYPE_UNDEFINED
|
|
};
|
|
|
|
struct RegisterData {
|
|
float multiplier;
|
|
PowermeterRegisters type;
|
|
uint16_t start_register;
|
|
ModbusFunctionType start_register_function;
|
|
uint16_t exponent_register;
|
|
ModbusFunctionType exponent_register_function;
|
|
uint16_t num_registers;
|
|
};
|
|
|
|
std::vector<RegisterData> pm_configuration;
|
|
|
|
types::powermeter::Powermeter pm_last_values;
|
|
|
|
std::thread output_thread;
|
|
|
|
/// @brief Remember whether we already logged the meter's unavailability.
|
|
bool meter_is_unavailable{false};
|
|
|
|
void init_default_values();
|
|
void init_register_assignments(const json& loaded_registers);
|
|
bool assign_register_data(const json& registers, const PowermeterRegisters register_type,
|
|
const std::string& register_selector);
|
|
void assign_register_sublevel_data(const json& registers, const PowermeterRegisters& register_type,
|
|
const std::string& register_selector, const std::string& sublevel_selector,
|
|
const uint8_t offset);
|
|
powermeterImpl::ModbusFunctionType select_modbus_function(const uint8_t function_code);
|
|
void read_powermeter_values();
|
|
bool read_register(const RegisterData& register_config);
|
|
bool process_response(
|
|
const RegisterData& register_data, const types::serial_comm_hub_requests::Result& register_message,
|
|
std::optional<std::reference_wrapper<const types::serial_comm_hub_requests::Result>> exponent_message);
|
|
float merge_register_values_into_element(const RegisterData& reg_data, const int16_t exponent,
|
|
const types::serial_comm_hub_requests::Result& reg_message);
|
|
void process_current_rate_message(const types::serial_comm_hub_requests::Result message);
|
|
void output_error_with_content(const types::serial_comm_hub_requests::Result& response);
|
|
// ev@3370e4dd-95f4-47a9-aaec-ea76f34a66c9:v1
|
|
};
|
|
|
|
// ev@3d7da0ad-02c2-493d-9920-0bbbd56b9876:v1
|
|
// insert other definitions here
|
|
// ev@3d7da0ad-02c2-493d-9920-0bbbd56b9876:v1
|
|
|
|
} // namespace main
|
|
} // namespace module
|
|
|
|
#endif // MAIN_POWERMETER_IMPL_HPP
|