.. _everest_modules_handwritten_GenericPowermeter:
.. *****************
.. GenericPowermeter
.. *****************
The module ``GenericPowermeter`` provides a connection to get data from
powermeters that are connected via Modbus RTU and whose data is automatically
updated (without startup configuration and/or request functions).
It supports both AC and DC powermeters.
To do so, a register configuration file is needed that describes which (ModbusRTU-)registers
are available on the device and what data they contain. The available data will then be used
to calculate the correct structure of data for the ``powermeter`` interface of EVerest.
Currently available powermeter configurations can be found in the module's ``models``
subdirectory.
To add a new powermeter to the set of available devices, there exists a ``template.yaml``
file in the ``models`` subdirectory which can be copied and filled with the new powermeter's
data from the datasheet.
Datasets in the configuration file
==================================
Available datasets for the module ``GenericPowermeter``
-------------------------------------------------------
This module can read the following parameters from a powermeter:
(for a description of the parameter values see interface ``powermeter``)
* energy_Wh_import
* energy_Wh_export
* power_W
* voltage_V
* VAR
* current_A
* frequency_Hz
Dataset description
-------------------
A typical dataset consists of the following parameters:
(<start_register> of length <num_registers>) * <multiplier> * 10^(<exponent_register>)
* <start_register> = the device's ModbusRTU register at which the value for the data of this
type is being stored (set to "0" if this value is not available in the powermeter)
* <function_code_start_reg> = ModbusRTU function code used to obtain this register's value
(currently implemented: ``3`` (``read holding registers``) and ``4`` (``read input registers``))
* <num_registers> = the number of registers to read from the address of <start_register>
* <multiplier> = a multiplier to manually (pre-)scale the register's value (i.e. set to ``0.001``
when the powermeter provides energy in ``kWh``, as the ``powermeter`` interface uses energy
in ``Wh``)
* <exponent_register> = the device's ModbusRTU register at which the exponent for the
register set is being stored (set to "0" if this value is not available in the powermeter)
* <function_code_exp_reg> = ModbusRTU function code used to obtain this register's exponent
(currently implemented: ``3`` (``read holding registers``) and ``4`` (``read input registers``))
Structure of datasets in the configuration file
-----------------------------------------------
Datasets are structured into two levels:
* first level : contains either DC value or, in AC case, sum total of all corresponding lines (L1/2/3)
* second level : contains AC values, split into their corresponding lines (L1/2/3)
Other things to note
--------------------
* if measuring AC, the first level of registers is always "total/sum" of a certain value and
the L1/2/3 registers are for the distinct phases
* if measuring DC, only use the first level of registers
Published variables
===================
powermeter
----------
The basic dataset of powermeter values as used in the EVerest ``powermeter`` interface.
This dataset will be periodically published by the module.
Provided commands
=================
get_signed_meter_value
----------------------
`currently not implemented`