settings: telemetry_enabled: false active_modules: auth: config_module: connection_timeout: 60 prioritize_authorization_over_stopping_transaction: true selection_algorithm: FindFirst ignore_connector_faults: true connections: evse_manager: - implementation_id: evse module_id: connector_1 token_provider: - implementation_id: main module_id: token_provider token_validator: - implementation_id: main module_id: token_validator module: Auth energy_manager: config_module: switch_3ph1ph_while_charging_mode: Never schedule_interval_duration: 60 schedule_total_duration: 10 debug: false connections: energy_trunk: - implementation_id: energy_grid module_id: grid_connection_point module: EnergyManager connector_1: config_module: ac_enforce_hlc: true ac_hlc_enabled: true ac_hlc_use_5percent: true ac_nominal_voltage: 230 charge_mode: DC connector_id: 1 ev_receipt_required: false evse_id: DE*PNX*E12345*1 has_ventilation: true payment_enable_contract: false payment_enable_eim: true session_logging: true session_logging_path: /tmp/everest-logs session_logging_xml: false switch_3ph1ph_delay_s: 5 switch_3ph1ph_cp_state: X1 cable_check_wait_below_60V_before_finish: false hack_allow_bpt_with_iso2: true connections: bsp: - implementation_id: main module_id: cb_bsp hlc: - implementation_id: charger module_id: iso15118_charger slac: - implementation_id: main module_id: slac powersupply_DC: - module_id: powersupply_dc implementation_id: main imd: - module_id: iso_monitor implementation_id: main over_voltage_monitor: - module_id: cb_ovm implementation_id: main module: EvseManager telemetry: id: 1 iso_monitor: config_implementation: main: imd_device_id: 3 connections: serial_comm_hub: - implementation_id: main module_id: comm_hub module: Bender_isoCHA425HV comm_hub: config_implementation: main: serial_port: /dev/cb_rs485 baudrate: 19200 parity: 2 module: SerialCommHub powersupply_dc: config_module: can_device: cb_can module: InfyPower_BEG1K075G grid_connection_point: config_module: fuse_limit_A: 16 phase_count: 3 connections: energy_consumer: - implementation_id: energy_grid module_id: external_limits_node module: EnergyNode external_limits_node: config_module: fuse_limit_A: 16 phase_count: 3 connections: energy_consumer: - implementation_id: energy_grid module_id: connector_1 module: EnergyNode iso15118_charger: config_module: device: cb_plc tls_security: prohibit connections: {} module: EvseV2G connections: security: - module_id: evse_security implementation_id: main evse_security: module: EvseSecurity config_module: private_key_password: "123456" persistent_store: config_module: sqlite_db_file_path: everest_persistent_store.db connections: {} module: PersistentStore slac: module: EvseSlac config_implementation: main: device: cb_plc token_provider: config_implementation: main: timeout: 10 token: DEADBEEF connections: evse: - implementation_id: evse module_id: connector_1 module: DummyTokenProvider token_validator: config_implementation: main: sleep: 0.25 validation_reason: Token seems valid validation_result: Accepted connections: {} module: DummyTokenValidator cb_bsp: connections: {} config_module: cfg_heartbeat_interval_ms: 500 module: evse_board_support_API cb_ovm: connections: {} config_module: cfg_heartbeat_interval_ms: 500 module: over_voltage_monitor_API external_limits: connections: energy_node: - implementation_id: external_limits module_id: external_limits_node config_module: cfg_heartbeat_interval_ms: 1000 cfg_communication_check_to_s: 0 module: external_energy_limits_consumer_API