description: >- This interface defines an isolation monitoring device (IMD) according to IEC 61557-8 for DC charging. This is used to verify isolation of the DC lines before starting high voltage charging and during charging. cmds: start: description: >- Start recurring isolation measurements. The device should monitor the isolation status until stopped and publish the resistance data in regular intervals. The actual interval is device dependent. stop: description: >- Stop recurring measurements. The device should stop to monitor the isolation resistance and stop publishing the data. start_self_test: description: >- Start self test. This will be done during the CableCheck phase, so a DC voltage will be present according to IEC 61851-23 (2023). The command should return immediately. The "self_test_result" variable must be published once the self testing is done. Note that on many hardware devices this can take a long time (e.g. 20 seconds). arguments: test_voltage_V: description: >- Specifies the test voltage [V] that is applied on the DC pins during self test. This can be used to verify the internal voltage measurement of the IMD. type: number vars: isolation_measurement: description: Isolation monitoring measurement results type: object $ref: /isolation_monitor#/IsolationMeasurement self_test_result: description: Indicates the self test is done and publishes the result. Set "true" for success, "false" for failure. type: boolean errors: - reference: /errors/isolation_monitor