settings: telemetry_enabled: true active_modules: api: connections: evse_manager: - implementation_id: evse module_id: connector_1 error_history: - module_id: error_history implementation_id: error_history module: API ev_api: connections: ev_manager: - implementation_id: ev_manager module_id: ev_manager module: EvAPI error_history: module: ErrorHistory config_implementation: error_history: database_path: /tmp/error_history.db auth: config_module: connection_timeout: 10 prioritize_authorization_over_stopping_transaction: true selection_algorithm: FindFirst ignore_connector_faults: true connections: evse_manager: - implementation_id: evse module_id: connector_1 token_provider: - implementation_id: main module_id: token_provider token_validator: - implementation_id: main module_id: token_validator module: Auth ev_manager: config_module: auto_enable: true auto_exec: false auto_exec_commands: sleep 1;iec_wait_pwr_ready;sleep 1;draw_power_regulated 16,3;sleep 30;unplug connector_id: 1 connections: ev: - implementation_id: ev module_id: iso15118_car ev_board_support: - implementation_id: ev_board_support module_id: connector_1_powerpath slac: - implementation_id: ev module_id: slac module: EvManager energy_manager: config_module: switch_3ph1ph_while_charging_mode: Both switch_3ph1ph_max_nr_of_switches_per_session: 5 switch_3ph1ph_time_hysteresis_s: 20 switch_3ph1ph_power_hysteresis_W: 1000 switch_3ph1ph_switch_limit_stickyness: SinglePhase schedule_interval_duration: 60 schedule_total_duration: 10 debug: false connections: energy_trunk: - implementation_id: energy_grid module_id: grid_connection_point module: EnergyManager connector_1: config_module: ac_enforce_hlc: false ac_hlc_enabled: true ac_hlc_use_5percent: false ac_nominal_voltage: 230 charge_mode: AC connector_id: 1 ev_receipt_required: false evse_id: DE*PNX*E12345*1 has_ventilation: true payment_enable_contract: true payment_enable_eim: true session_logging: true session_logging_path: /tmp/everest-logs session_logging_xml: false switch_3ph1ph_delay_s: 5 switch_3ph1ph_cp_state: X1 connections: bsp: - implementation_id: board_support module_id: connector_1_powerpath hlc: - implementation_id: charger module_id: iso15118_charger powermeter_grid_side: - implementation_id: powermeter module_id: connector_1_powerpath slac: - implementation_id: evse module_id: slac ac_rcd: - implementation_id: rcd module_id: connector_1_powerpath connector_lock: - implementation_id: connector_lock module_id: connector_1_powerpath module: EvseManager telemetry: id: 1 grid_connection_point: config_module: fuse_limit_A: 40 phase_count: 3 connections: energy_consumer: - implementation_id: energy_grid module_id: connector_1 module: EnergyNode iso15118_car: config_module: device: auto supported_ISO15118_2: true connections: {} module: PyEvJosev iso15118_charger: config_module: device: auto tls_security: allow supported_DIN70121: false module: EvseV2G connections: security: - module_id: evse_security implementation_id: main evse_security: module: EvseSecurity config_module: private_key_password: "123456" persistent_store: config_module: sqlite_db_file_path: everest_persistent_store.db connections: {} module: PersistentStore setup: config_module: initialized_by_default: true localization: true online_check_host: lfenergy.org setup_simulation: true setup_wifi: false connections: store: - implementation_id: main module_id: persistent_store module: Setup slac: module: SlacSimulator token_provider: config_implementation: main: timeout: 10 token: DEADBEEF connections: evse: - implementation_id: evse module_id: connector_1 module: DummyTokenProvider token_validator: config_implementation: main: sleep: 0.25 validation_reason: Token seems valid validation_result: Accepted connections: {} module: DummyTokenValidator connector_1_powerpath: config_module: connector_id: 1 connections: {} module: YetiSimulator telemetry: id: 1 'x-module-layout': api: position: x: 33 y: 13 terminals: bottom: [] left: - id: evse_manager interface: evse_manager type: requirement right: [] top: [] auth: position: x: 33 y: 2 terminals: bottom: - id: main interface: auth type: provide - id: reservation interface: reservation type: provide left: - id: evse_manager interface: evse_manager type: requirement right: - id: token_validator interface: auth_token_validator type: requirement top: - id: token_provider interface: auth_token_provider type: requirement ev_manager: position: x: 53 y: 33 terminals: bottom: [] left: - id: simulation_control interface: yeti_simulation_control type: requirement - id: slac interface: slac type: requirement right: - id: main interface: ev_manager type: provide top: - id: ev interface: ISO15118_ev type: requirement connector_1: position: x: 13 y: 23 terminals: bottom: - id: powersupply_DC interface: power_supply_DC type: requirement - id: imd interface: isolation_monitor type: requirement - id: powermeter_car_side interface: powermeter type: requirement - id: token_provider interface: auth_token_provider type: provide - id: slac interface: slac type: requirement left: - id: hlc interface: ISO15118_charger type: requirement right: - id: bsp interface: board_support_AC type: requirement - id: powermeter_grid_side interface: powermeter type: requirement top: - id: energy_grid interface: energy type: provide - id: evse interface: evse_manager type: provide connector_1_powerpath: position: x: 33 y: 23 terminals: bottom: - id: debug_keepalive interface: debug_json type: provide - id: debug_powermeter interface: debug_json type: provide - id: debug_yeti interface: debug_json type: provide - id: yeti_extras interface: yeti_extras type: provide - id: debug_state interface: debug_json type: provide left: - id: board_support interface: board_support_AC type: provide - id: powermeter interface: powermeter type: provide right: - id: yeti_simulation_control interface: yeti_simulation_control type: provide top: [] energy_manager: position: x: -5 y: 2 terminals: bottom: - id: energy_trunk interface: energy type: requirement left: [] right: - id: main interface: energy_manager type: provide top: [] grid_connection_point: position: x: -5 y: 13 terminals: bottom: [] left: - id: price_information interface: energy_price_information type: requirement - id: powermeter interface: powermeter type: requirement right: - id: external_limits interface: external_energy_limits type: provide - id: energy_consumer interface: energy type: requirement top: - id: energy_grid interface: energy type: provide iso15118_car: position: x: 53 y: 23 terminals: bottom: - id: ev interface: ISO15118_ev type: provide left: [] right: [] top: [] iso15118_charger: position: x: -5 y: 23 terminals: bottom: [] left: [] right: - id: charger interface: ISO15118_charger type: provide top: [] persistent_store: position: x: -5 y: 40 terminals: bottom: [] left: [] right: - id: main interface: kvs type: provide top: [] setup: position: x: 13 y: 40 terminals: bottom: [] left: - id: store interface: kvs type: requirement right: [] top: [] slac: position: x: 33 y: 33 terminals: bottom: [] left: - id: evse interface: slac type: provide right: - id: ev interface: slac type: provide top: [] token_provider: position: x: 33 y: -9 terminals: bottom: - id: main interface: auth_token_provider type: provide left: - id: evse interface: evse_manager type: requirement right: [] top: [] token_validator: position: x: 51 y: 2 terminals: bottom: [] left: - id: main interface: auth_token_validator type: provide right: [] top: []