settings: telemetry_enabled: true active_modules: api: module: RpcApi connections: evse_manager: - module_id: connector_1 implementation_id: evse evse_energy_sink: - module_id: grid_connection_point implementation_id: external_limits - module_id: api_sink_1_evsemgr implementation_id: external_limits auth: module: Auth config_module: connection_timeout: 10 prioritize_authorization_over_stopping_transaction: true selection_algorithm: FindFirst ignore_connector_faults: true connections: evse_manager: - implementation_id: evse module_id: connector_1 token_provider: - implementation_id: main module_id: token_provider token_validator: - implementation_id: main module_id: token_validator ev_manager: module: EvManager config_module: auto_enable: true auto_exec: false auto_exec_commands: sleep 1;iec_wait_pwr_ready;sleep 1;draw_power_regulated 16,3;sleep 30;unplug connector_id: 1 connections: ev: - implementation_id: ev module_id: iso15118_car ev_board_support: - implementation_id: ev_board_support module_id: connector_1_powerpath slac: - implementation_id: ev module_id: slac energy_manager: module: EnergyManager config_module: switch_3ph1ph_while_charging_mode: Both switch_3ph1ph_max_nr_of_switches_per_session: 5 switch_3ph1ph_time_hysteresis_s: 20 switch_3ph1ph_power_hysteresis_W: 1000 switch_3ph1ph_switch_limit_stickyness: SinglePhase schedule_interval_duration: 60 schedule_total_duration: 10 debug: false connections: energy_trunk: - implementation_id: energy_grid module_id: grid_connection_point api_sink_1_evsemgr: module: EnergyNode mapping: module: evse: 1 config_module: fuse_limit_A: 32.0 phase_count: 3 connections: energy_consumer: - module_id: connector_1 implementation_id: energy_grid connector_1: module: EvseManager mapping: module: evse: 1 config_module: ac_enforce_hlc: false ac_hlc_enabled: true ac_hlc_use_5percent: false ac_nominal_voltage: 230 charge_mode: AC connector_id: 1 ev_receipt_required: false evse_id: DE*PNX*E12345*1 has_ventilation: true payment_enable_contract: true payment_enable_eim: true session_logging: true session_logging_path: /tmp/everest-logs session_logging_xml: false switch_3ph1ph_delay_s: 5 switch_3ph1ph_cp_state: X1 connections: bsp: - implementation_id: board_support module_id: connector_1_powerpath hlc: - implementation_id: charger module_id: iso15118_charger powermeter_grid_side: - implementation_id: powermeter module_id: connector_1_powerpath slac: - implementation_id: evse module_id: slac ac_rcd: - implementation_id: rcd module_id: connector_1_powerpath connector_lock: - implementation_id: connector_lock module_id: connector_1_powerpath telemetry: id: 1 grid_connection_point: module: EnergyNode mapping: module: evse: 0 config_module: fuse_limit_A: 40 phase_count: 3 connections: energy_consumer: - implementation_id: energy_grid module_id: api_sink_1_evsemgr iso15118_car: module: PyEvJosev config_module: device: auto supported_ISO15118_2: true iso15118_charger: module: EvseV2G config_module: device: auto tls_security: allow supported_DIN70121: false connections: security: - module_id: evse_security implementation_id: main evse_security: module: EvseSecurity config_module: private_key_password: "123456" persistent_store: module: PersistentStore config_module: sqlite_db_file_path: everest_persistent_store.db setup: module: Setup config_module: initialized_by_default: true localization: true online_check_host: lfenergy.org setup_simulation: true setup_wifi: false connections: store: - implementation_id: main module_id: persistent_store slac: module: SlacSimulator token_provider: module: DummyTokenProvider config_implementation: main: timeout: 10 token: DEADBEEF connections: evse: - implementation_id: evse module_id: connector_1 token_validator: module: DummyTokenValidator config_implementation: main: sleep: 0.25 validation_reason: Token seems valid validation_result: Accepted connector_1_powerpath: module: YetiSimulator config_module: connector_id: 1 telemetry: id: 1