active_modules: iso15118_charger: module: EvseV2G config_module: device: auto tls_security: allow connections: security: - module_id: evse_security implementation_id: main iso15118_car: module: PyEvJosev config_module: device: auto supported_DIN70121: true supported_ISO15118_2: true evse_manager: module: EvseManager config_module: connector_id: 1 evse_id: DE*PNX*E12345*1 evse_id_din: 49A80737A45678 session_logging: true session_logging_xml: false session_logging_path: /tmp/everest-logs charge_mode: DC hack_allow_bpt_with_iso2: true connections: bsp: - module_id: yeti_driver implementation_id: board_support powermeter_car_side: - module_id: powersupply_dc implementation_id: powermeter slac: - module_id: slac implementation_id: evse hlc: - module_id: iso15118_charger implementation_id: charger powersupply_DC: - module_id: powersupply_dc implementation_id: main imd: - module_id: imd implementation_id: main over_voltage_monitor: - module_id: ovm implementation_id: main powersupply_dc: module: DCSupplySimulator yeti_driver: module: YetiSimulator config_module: connector_id: 1 slac: module: SlacSimulator imd: config_implementation: main: selftest_success: true resistance_F_Ohm: 900000 module: IMDSimulator ovm: module: OVMSimulator config_implementation: main: simulate_emergency_shutdown: false simulate_error_delay: 5 connections: power_supply: - module_id: powersupply_dc implementation_id: main ev_manager: module: EvManager config_module: connector_id: 1 auto_enable: true auto_exec: false auto_exec_commands: sleep 1;iec_wait_pwr_ready;sleep 1;draw_power_regulated 16,3;sleep 30;unplug dc_target_current: 20 dc_target_voltage: 400 connections: ev_board_support: - module_id: yeti_driver implementation_id: ev_board_support ev: - module_id: iso15118_car implementation_id: ev slac: - module_id: slac implementation_id: ev auth: module: Auth config_module: connection_timeout: 10 selection_algorithm: FindFirst connections: token_provider: - module_id: token_provider implementation_id: main token_validator: - module_id: token_validator implementation_id: main evse_manager: - module_id: evse_manager implementation_id: evse token_provider: module: DummyTokenProvider config_implementation: main: token: TOKEN1 connections: evse: - module_id: evse_manager implementation_id: evse token_validator: module: DummyTokenValidator config_implementation: main: validation_result: Accepted validation_reason: Token seems valid sleep: 0.25 evse_security: module: EvseSecurity config_module: private_key_password: "123456" energy_manager: module: EnergyManager config_module: schedule_total_duration: 1 schedule_interval_duration: 60 debug: false connections: energy_trunk: - module_id: grid_connection_point implementation_id: energy_grid grid_connection_point: module: EnergyNode config_module: fuse_limit_A: 40.0 phase_count: 3 connections: price_information: [] energy_consumer: - module_id: api_sink implementation_id: energy_grid powermeter: - module_id: yeti_driver implementation_id: powermeter api_sink: module: EnergyNode mapping: module: evse: 1 config_module: fuse_limit_A: 32.0 phase_count: 3 connections: energy_consumer: - module_id: evse_manager implementation_id: energy_grid api: module: API connections: evse_manager: - module_id: evse_manager implementation_id: evse error_history: - module_id: error_history implementation_id: error_history evse_energy_sink: - module_id: api_sink implementation_id: external_limits ev_api: module: EvAPI connections: ev_manager: - implementation_id: ev_manager module_id: ev_manager error_history: module: ErrorHistory config_implementation: error_history: database_path: /tmp/error_history.db x-module-layout: iso15118_charger: position: x: 12 'y': -7 terminals: top: [] right: - id: charger interface: ISO15118_charger type: provide - id: extensions interface: iso15118_extensions type: provide bottom: [] left: - id: security interface: evse_security type: requirement iso15118_car: position: x: -8 'y': 35 terminals: top: [] right: - id: ev interface: ISO15118_ev type: provide bottom: [] left: [] evse_manager: position: x: 33 'y': 14 terminals: top: [] right: - id: evse interface: evse_manager type: provide - id: energy_grid interface: energy type: provide - id: random_delay interface: uk_random_delay type: provide - id: token_provider interface: auth_token_provider type: provide bottom: [] left: - id: hlc interface: ISO15118_charger type: requirement - id: over_voltage_monitor interface: over_voltage_monitor type: requirement - id: imd interface: isolation_monitor type: requirement - id: powersupply_DC interface: power_supply_DC type: requirement - id: ac_rcd interface: ac_rcd type: requirement - id: connector_lock interface: connector_lock type: requirement - id: powermeter_grid_side interface: powermeter type: requirement - id: store interface: kvs type: requirement - id: powermeter_car_side interface: powermeter type: requirement - id: slac interface: slac type: requirement - id: bsp interface: evse_board_support type: requirement powersupply_dc: position: x: -8 'y': 14 terminals: top: [] right: - id: main interface: power_supply_DC type: provide - id: powermeter interface: powermeter type: provide bottom: [] left: [] yeti_driver: position: x: -8 'y': 28 terminals: top: [] right: - id: board_support interface: evse_board_support type: provide - id: connector_lock interface: connector_lock type: provide - id: ev_board_support interface: ev_board_support type: provide - id: powermeter interface: powermeter type: provide - id: rcd interface: ac_rcd type: provide bottom: [] left: [] slac: position: x: -8 'y': 21 terminals: top: [] right: - id: evse interface: slac type: provide - id: ev interface: ev_slac type: provide bottom: [] left: [] imd: position: x: -8 'y': 7 terminals: top: [] right: - id: main interface: isolation_monitor type: provide bottom: [] left: [] ovm: position: x: -8 'y': -0.0 terminals: top: [] right: - id: main interface: over_voltage_monitor type: provide bottom: [] left: [] ev_manager: position: x: 33 'y': 23 terminals: top: [] right: - id: main interface: car_simulator type: provide bottom: [] left: - id: powermeter interface: powermeter type: requirement - id: slac interface: ev_slac type: requirement - id: ev_board_support interface: ev_board_support type: requirement - id: ev interface: ISO15118_ev type: requirement auth: position: x: 77 'y': 6 terminals: top: [] right: - id: main interface: auth type: provide - id: reservation interface: reservation type: provide bottom: [] left: - id: token_validator interface: auth_token_validator type: requirement - id: kvs interface: kvs type: requirement - id: token_provider interface: auth_token_provider type: requirement - id: evse_manager interface: evse_manager type: requirement token_provider: position: x: 54 'y': 4 terminals: top: [] right: - id: main interface: auth_token_provider type: provide bottom: [] left: - id: evse interface: evse_manager type: requirement token_validator: position: x: 54 'y': -4 terminals: top: [] right: - id: main interface: auth_token_validator type: provide bottom: [] left: [] evse_security: position: x: -8 'y': -7 terminals: top: [] right: - id: main interface: evse_security type: provide bottom: [] left: [] energy_manager: position: x: 77 'y': 21 terminals: top: [] right: - id: main interface: energy_manager type: provide bottom: [] left: - id: energy_trunk interface: energy type: requirement grid_connection_point: position: x: 54 'y': 29 terminals: top: [] right: - id: energy_grid interface: energy type: provide - id: external_limits interface: external_energy_limits type: provide bottom: [] left: - id: energy_consumer interface: energy type: requirement - id: powermeter interface: powermeter type: requirement - id: price_information interface: energy_price_information type: requirement api: position: x: 77 'y': 13 terminals: top: [] right: [] bottom: [] left: - id: evse_energy_sink interface: external_energy_limits type: requirement - id: evse_manager interface: evse_manager type: requirement - id: ocpp interface: ocpp type: requirement - id: random_delay interface: uk_random_delay type: requirement - id: error_history interface: error_history type: requirement error_history: position: x: 54 'y': 17 terminals: top: [] right: - id: error_history interface: error_history type: provide bottom: [] left: []