active_modules: iso15118_charger: module: Evse15118D20 config_module: device: auto connections: security: - module_id: evse_security implementation_id: main iso15118_car: module: PyEvJosev config_module: device: auto supported_DIN70121: false supported_ISO15118_2: false supported_ISO15118_20_DC: false supported_ISO15118_20_AC: true supported_d20_energy_services: "AC_BPT,AC" tls_active: true enable_tls_1_3: true evse_manager: module: EvseManager config_module: ac_enforce_hlc: false ac_hlc_enabled: true ac_hlc_use_5percent: false ac_nominal_voltage: 230 supported_iso_ac_bpt: true charge_mode: AC connector_id: 1 ev_receipt_required: false evse_id: DE*PNX*E12345*1 has_ventilation: true payment_enable_contract: false payment_enable_eim: true session_logging: true session_logging_path: /tmp/everest-logs session_logging_xml: false switch_3ph1ph_delay_s: 5 switch_3ph1ph_cp_state: X1 bpt_channel: Unified bpt_generator_mode: GridFollowing bpt_grid_code_island_method: Passive connections: bsp: - module_id: connector_1_powerpath implementation_id: board_support hlc: - module_id: iso15118_charger implementation_id: charger powermeter_car_side: - module_id: connector_1_powerpath implementation_id: powermeter slac: - module_id: slac implementation_id: evse ac_rcd: - implementation_id: rcd module_id: connector_1_powerpath connector_lock: - implementation_id: connector_lock module_id: connector_1_powerpath connector_1_powerpath: config_module: connector_id: 1 connections: {} module: YetiSimulator telemetry: id: 1 slac: module: SlacSimulator ev_manager: module: EvManager config_module: connector_id: 1 auto_enable: true auto_exec: false auto_exec_commands: sleep 3;iso_wait_slac_matched;iso_start_v2g_session AC;iso_wait_pwr_ready;iso_draw_power_regulated 16,3;iso_wait_for_stop 20;iso_wait_v2g_session_stopped;unplug connections: ev_board_support: - module_id: connector_1_powerpath implementation_id: ev_board_support ev: - module_id: iso15118_car implementation_id: ev slac: - module_id: slac implementation_id: ev auth: module: Auth config_module: connection_timeout: 10 selection_algorithm: FindFirst connections: token_provider: - module_id: token_provider implementation_id: main token_validator: - module_id: token_validator implementation_id: main evse_manager: - module_id: evse_manager implementation_id: evse token_provider: module: DummyTokenProvider config_implementation: main: timeout: 10 token: DEADBEEF connections: evse: - module_id: evse_manager implementation_id: evse token_validator: module: DummyTokenValidator config_implementation: main: validation_result: Accepted validation_reason: Token seems valid sleep: 0.25 evse_security: module: EvseSecurity config_module: private_key_password: "123456" energy_manager: module: EnergyManager config_module: schedule_total_duration: 1 schedule_interval_duration: 60 debug: false connections: energy_trunk: - module_id: grid_connection_point implementation_id: energy_grid grid_connection_point: module: EnergyNode config_module: fuse_limit_A: 40.0 phase_count: 3 connections: price_information: [] energy_consumer: - module_id: api_sink implementation_id: energy_grid powermeter: - module_id: connector_1_powerpath implementation_id: powermeter api_sink: module: EnergyNode mapping: module: evse: 1 config_module: fuse_limit_A: 32.0 phase_count: 3 connections: energy_consumer: - module_id: evse_manager implementation_id: energy_grid api: module: API connections: evse_manager: - module_id: evse_manager implementation_id: evse error_history: - module_id: error_history implementation_id: error_history evse_energy_sink: - module_id: api_sink implementation_id: external_limits error_history: module: ErrorHistory config_implementation: error_history: database_path: /tmp/error_history.db x-module-layout: {}