settings: telemetry_enabled: false active_modules: auth: config_module: connection_timeout: 60 prioritize_authorization_over_stopping_transaction: true selection_algorithm: FindFirst ignore_connector_faults: true connections: evse_manager: - implementation_id: evse module_id: connector_1 token_provider: - implementation_id: main module_id: token_provider token_validator: - implementation_id: main module_id: token_validator module: Auth energy_manager: config_module: switch_3ph1ph_while_charging_mode: Both switch_3ph1ph_max_nr_of_switches_per_session: 5 switch_3ph1ph_time_hysteresis_s: 20 switch_3ph1ph_power_hysteresis_W: 1000 switch_3ph1ph_switch_limit_stickyness: SinglePhase schedule_interval_duration: 60 schedule_total_duration: 10 debug: false connections: energy_trunk: - implementation_id: energy_grid module_id: grid_connection_point module: EnergyManager connector_1: config_module: ac_enforce_hlc: true ac_hlc_enabled: true ac_hlc_use_5percent: true ac_nominal_voltage: 230 charge_mode: AC connector_id: 1 ev_receipt_required: false evse_id: DE*PNX*E12345*1 has_ventilation: true payment_enable_contract: false payment_enable_eim: true session_logging: true session_logging_path: /tmp/everest-logs session_logging_xml: false switch_3ph1ph_delay_s: 5 switch_3ph1ph_cp_state: X1 bpt_channel: Unified bpt_generator_mode: GridFollowing bpt_grid_code_island_method: Passive connections: bsp: - implementation_id: main module_id: cb_bsp hlc: - implementation_id: charger module_id: iso15118_charger powermeter_grid_side: - implementation_id: main module_id: powermeter slac: - implementation_id: main module_id: slac ac_rcd: - implementation_id: rcd module_id: cb_bsp connector_lock: - implementation_id: connector_lock module_id: cb_bsp module: EvseManager telemetry: id: 1 grid_connection_point: config_module: fuse_limit_A: 16 phase_count: 3 connections: energy_consumer: - implementation_id: energy_grid module_id: connector_1 module: EnergyNode iso15118_charger: module: Evse15118D20 config_module: device: cb_plc connections: security: - module_id: evse_security implementation_id: main connections: security: - module_id: evse_security implementation_id: main evse_security: module: EvseSecurity config_module: private_key_password: "123456" persistent_store: config_module: sqlite_db_file_path: everest_persistent_store.db connections: {} module: PersistentStore slac: module: EvseSlac config_implementation: main: device: cb_plc token_provider: config_implementation: main: timeout: 10 token: DEADBEEF connections: evse: - implementation_id: evse module_id: connector_1 module: DummyTokenProvider token_validator: config_implementation: main: sleep: 0.25 validation_reason: Token seems valid validation_result: Accepted connections: {} module: DummyTokenValidator cb_bsp: connections: {} module: evse_board_support_API powermeter: module: GenericPowermeter config_implementation: main: model: Eastron_SDM72DM powermeter_device_id: 1 connections: serial_comm_hub: - module_id: commhub implementation_id: main commhub: module: SerialCommHub config_implementation: main: serial_port: /dev/cb_rs485