Add extracted tools: CitrineOS, OpenOCPP, ShapeShifter
- CitrineOS core extracted (CSMS OCPP 2.0.1) - OpenOCPP extracted (firmware OCPP 1.6J/2.0.1) - ShapeShifter library installed (pip install -e) - ShapeShifter specification extracted - EVerest extracted TODO updated with progress
This commit is contained in:
@@ -0,0 +1,96 @@
|
||||
.. _everest_modules_handwritten_GenericPowermeter:
|
||||
|
||||
.. *****************
|
||||
.. GenericPowermeter
|
||||
.. *****************
|
||||
|
||||
The module ``GenericPowermeter`` provides a connection to get data from
|
||||
powermeters that are connected via Modbus RTU and whose data is automatically
|
||||
updated (without startup configuration and/or request functions).
|
||||
|
||||
It supports both AC and DC powermeters.
|
||||
|
||||
To do so, a register configuration file is needed that describes which (ModbusRTU-)registers
|
||||
are available on the device and what data they contain. The available data will then be used
|
||||
to calculate the correct structure of data for the ``powermeter`` interface of EVerest.
|
||||
|
||||
Currently available powermeter configurations can be found in the module's ``models``
|
||||
subdirectory.
|
||||
|
||||
To add a new powermeter to the set of available devices, there exists a ``template.yaml``
|
||||
file in the ``models`` subdirectory which can be copied and filled with the new powermeter's
|
||||
data from the datasheet.
|
||||
|
||||
|
||||
Datasets in the configuration file
|
||||
==================================
|
||||
|
||||
Available datasets for the module ``GenericPowermeter``
|
||||
-------------------------------------------------------
|
||||
|
||||
This module can read the following parameters from a powermeter:
|
||||
|
||||
(for a description of the parameter values see interface ``powermeter``)
|
||||
|
||||
* energy_Wh_import
|
||||
* energy_Wh_export
|
||||
* power_W
|
||||
* voltage_V
|
||||
* VAR
|
||||
* current_A
|
||||
* frequency_Hz
|
||||
|
||||
Dataset description
|
||||
-------------------
|
||||
|
||||
A typical dataset consists of the following parameters:
|
||||
|
||||
(<start_register> of length <num_registers>) * <multiplier> * 10^(<exponent_register>)
|
||||
|
||||
* <start_register> = the device's ModbusRTU register at which the value for the data of this
|
||||
type is being stored (set to "0" if this value is not available in the powermeter)
|
||||
* <function_code_start_reg> = ModbusRTU function code used to obtain this register's value
|
||||
(currently implemented: ``3`` (``read holding registers``) and ``4`` (``read input registers``))
|
||||
* <num_registers> = the number of registers to read from the address of <start_register>
|
||||
* <multiplier> = a multiplier to manually (pre-)scale the register's value (i.e. set to ``0.001``
|
||||
when the powermeter provides energy in ``kWh``, as the ``powermeter`` interface uses energy
|
||||
in ``Wh``)
|
||||
* <exponent_register> = the device's ModbusRTU register at which the exponent for the
|
||||
register set is being stored (set to "0" if this value is not available in the powermeter)
|
||||
* <function_code_exp_reg> = ModbusRTU function code used to obtain this register's exponent
|
||||
(currently implemented: ``3`` (``read holding registers``) and ``4`` (``read input registers``))
|
||||
|
||||
|
||||
Structure of datasets in the configuration file
|
||||
-----------------------------------------------
|
||||
|
||||
Datasets are structured into two levels:
|
||||
|
||||
* first level : contains either DC value or, in AC case, sum total of all corresponding lines (L1/2/3)
|
||||
* second level : contains AC values, split into their corresponding lines (L1/2/3)
|
||||
|
||||
Other things to note
|
||||
--------------------
|
||||
|
||||
* if measuring AC, the first level of registers is always "total/sum" of a certain value and
|
||||
the L1/2/3 registers are for the distinct phases
|
||||
* if measuring DC, only use the first level of registers
|
||||
|
||||
Published variables
|
||||
===================
|
||||
|
||||
powermeter
|
||||
----------
|
||||
|
||||
The basic dataset of powermeter values as used in the EVerest ``powermeter`` interface.
|
||||
This dataset will be periodically published by the module.
|
||||
|
||||
|
||||
Provided commands
|
||||
=================
|
||||
|
||||
get_signed_meter_value
|
||||
----------------------
|
||||
|
||||
`currently not implemented`
|
||||
|
||||