Add extracted tools: CitrineOS, OpenOCPP, ShapeShifter
- CitrineOS core extracted (CSMS OCPP 2.0.1) - OpenOCPP extracted (firmware OCPP 1.6J/2.0.1) - ShapeShifter library installed (pip install -e) - ShapeShifter specification extracted - EVerest extracted TODO updated with progress
This commit is contained in:
@@ -0,0 +1,76 @@
|
||||
description: Carlo Gavazzi EM580 powermeter
|
||||
provides:
|
||||
main:
|
||||
description: Implementation of the driver functionality
|
||||
interface: powermeter
|
||||
config:
|
||||
powermeter_device_id:
|
||||
description: The powermeter's address on the serial bus
|
||||
type: integer
|
||||
minimum: 0
|
||||
maximum: 255
|
||||
default: 1
|
||||
communication_retry_count:
|
||||
description: Number of retries for communication operations before giving up.
|
||||
type: integer
|
||||
minimum: 1
|
||||
maximum: 100
|
||||
default: 3
|
||||
communication_retry_delay_ms:
|
||||
description: Delay in milliseconds between retry attempts.
|
||||
type: integer
|
||||
minimum: 10
|
||||
maximum: 10000
|
||||
default: 500
|
||||
communication_error_pause_delay_s:
|
||||
description: Delay in seconds before retrying communication in the live measurement thread after a failure. Default 10 seconds. Applies to initial communication too.
|
||||
type: integer
|
||||
minimum: 1
|
||||
maximum: 600
|
||||
default: 10
|
||||
initial_connection_retry_count:
|
||||
description: Number of retries for initial connection/signature config read during module initialization. 0 means infinite retries.
|
||||
type: integer
|
||||
minimum: 0
|
||||
maximum: 100
|
||||
default: 10
|
||||
initial_connection_retry_delay_ms:
|
||||
description: Delay in milliseconds between retry attempts during initialization.
|
||||
type: integer
|
||||
minimum: 100
|
||||
maximum: 60000
|
||||
default: 2000
|
||||
timezone_offset_minutes:
|
||||
description: Timezone offset from UTC in minutes (e.g., 60 for UTC+1, -300 for UTC-5). Range -1440 to +1440 minutes. Default is 0 (UTC).
|
||||
type: integer
|
||||
minimum: -1440
|
||||
maximum: 1440
|
||||
default: 0
|
||||
live_measurement_interval_ms:
|
||||
description: Interval in milliseconds between live powermeter reads and publishes. Default 1000 ms (once per second). Allowed range 500-60000 ms (twice per second to once per minute).
|
||||
type: integer
|
||||
minimum: 500
|
||||
maximum: 60000
|
||||
default: 1000
|
||||
device_state_read_interval_ms:
|
||||
description: Interval in milliseconds between reading the device state bitfield (used for VendorError reporting). Default 10000 ms (once per 10 seconds). Allowed range 500-60000 ms.
|
||||
type: integer
|
||||
minimum: 500
|
||||
maximum: 60000
|
||||
default: 10000
|
||||
public_key_format:
|
||||
description: The key format to use for the public key.
|
||||
type: string
|
||||
enum:
|
||||
- binary
|
||||
- der
|
||||
default: binary
|
||||
requires:
|
||||
modbus:
|
||||
interface: serial_communication_hub
|
||||
metadata:
|
||||
license: https://opensource.org/licenses/Apache-2.0
|
||||
authors:
|
||||
- florin.mihut@pionix.com
|
||||
enable_external_mqtt: false
|
||||
|
||||
Reference in New Issue